Feature;Astra-20;Astra-100;Astra-100АТ
Maximum output power;<b>20 W</b>; 100 W;100 W;
Maximum output voltage;400 V; 400 V;<b>700 V</b>
Output current values and corresponding ranges of supply line contact resistance values;<i>1.0 mA</i> : 8.0 ÷ 400 kOhm<br>—<br><i>2.0 mA</i> : 4.0 ÷ 200 kOhm<br>—<br><i>5.0 mA</i> : 1.6 ÷ 80 kOhm<br>—<br><i>10.0 mA</i> : 0.8 ÷ 40 kOhm<br><i>14.1 mA</i> : 0.56 ÷ 28.4 kOhm<br><i>20.0 mA</i> : 0,4 ÷ 20 kOhm<br><i>31.6 mA</i> : 0.25 ÷ 12.7 kOhm<br><i>50.0 mA</i> : 160 ÷ 8000 Ohm<br><i>70.7 mA</i> : 80 ÷ 4000 Ohm<br><i>100 mA</i> : 40 ÷ 2000 Ohm; <i>1.0 mA</i> : 8.0 ÷ 400 kOhm<br>—<br><i>2.0 mA</i> : 4.0 ÷ 200 kOhm<br>—<br><i>5.0 mA</i> : 1.5 ÷ 80 kOhm<br>—<br><i>10.0 mA</i> : 0.8 ÷ 40 kOhm<br><i>14.1 mA</i> : 0.6 ÷ 28 kOhm<br><i>20.0 mA</i> : 0,4 ÷ 20 kOhm<br><i>31.6 mA</i> : 0.25 ÷ 12.6 kOhm<br><i>50.0 mA</i> : 160 ÷ 8000 Ohm<br><i>70.7 mA</i> : 113 ÷ 5660 Ohm<br><i>100 mA</i> : 80 ÷ 4000 Ohm<br><i>141 mA</i> : 57 ÷ 2800 Ohm<br>—<br><i>200 mA</i> : 40 ÷ 2000 Ohm<br>—<br><i>316 mA</i> : 20 ÷ 1000 Ohm<br><i>500 mA</i> : 8 ÷ 400 Ohm<br><i>707 mA</i> : 4 ÷ 200 Ohm<br>—<br><i>1000 mA</i> : 2 ÷ 100 Ohm;<i>1.0 mA</i> : 15.0 ÷ 700 kOhm<br><i>1.5 mA</i> : 10.0 ÷ 467 kOhm<br><i>2.0 mA</i> : 7.5 ÷ 350 kOhm<br><i>3.50 mA</i> : 4.3 ÷ 200 kOhm<br><i>5.0 mA</i> : 3.0 ÷ 140 kOhm<br><i>7.5 mA</i> : 2.0 ÷ 93 kOhm<br><i>10.0 mA</i> : 1.5 ÷ 70 kOhm<br><i>15.0 mA</i> : 1.0 ÷ 46.7 kOhm<br><i>20.0 mA</i> : 0.75 ÷ 35 kOhm<br><i>35 mA</i> : 0.43 ÷ 20.0 kOhm<br><i>50.0 mA</i> : 0.3 ÷ 14 kOhm<br><i>75 mA</i> : 0.2 ÷ 93 kOhm<br><i>100 mA</i> : 0.15 ÷ 7 kOhm<br><i>130 mA</i> : 0.116 ÷ 5.38 kOhm<br><i>160 mA</i> : 0.079 ÷ 3.9 kOhm<br><i>200 mA</i> : 0.05 ÷ 2.5 kOhm<br><i>250 mA</i> : 0.032 ÷ 1.6 kOhm<br><i>350 mA</i> : 16.5 ÷ 817 Ohm<br><i>500 mA</i> : 8.0 ÷ 400 Ohm<br><i>700 mA</i> : 4.1 ÷ 204 Ohm<br><i>850 mA</i> : 2.8 ÷ 139 Ohm<br><i>1000 mA</i> : 2.0 ÷ 100 Ohm;
Output current form;RPI-1 («meander», rectangular multipolar pulses without pause). <br>—<br><br>Sweep-signal (combination of RPI-1 with different frequency).;RPI-1 («meander», rectangular multipolar pulses without pause). <br>—<br><br>Sweep-signal (combination of RPI-1 with different frequency).; RPI-1 («meander», rectangular multipolar pulses without pause). <br><b>RPI-2</b> («meander», rectangular multipolar pulses with pause). <br>Sweep-signal (combination of RPI-1 and PRI-2 with different frequency).
Operating frequency (Hz):;1-100 mA: 0.076, 0.153, 0.305, 0.610, 1.22, 2.44, 4.88, 9.77, 19.5, 39.1, 78.1, 156, 312.5, 625 Hz. <br>10-100 mA: 1250, 2500 Hz.;Set 1 (16 frequencies): 0.076‑2500 Hz.<br>Set 2 (16 frequencies): 0.0625‑2048 Hz.<br>Set 3 (14 frequencies): 0.083‑683 Hz.; Four sets of 16 frequencies in RPI-1 mode:<br>Set 1: 0.076-2500 Hz<br>Set 2: 0.0625-2048 Hz<br>Set 3: 0.08333-2730.(6) Hz<br>Set 4: 0.061-2000 Hz
Efficiency; to 85%; to 80%; to 85%
Absolute error of factory adjustment of output currents at room temperature, 12.6/14.8 V supply voltage, 0.3 Hz frequency and 30% of maximum load;not more than 0.25% (output current value is defined as the average value of positive and negative polarity currents); not more than 0.25% (output current value is defined as the average value of positive and negative polarity currents); not more than 0.25% (output current value is defined as the average value of positive and negative polarity currents)
Instability of output currents when the load varies from 3% to 85% of maximum, at room temperature, at a frequency of 0.3 Hz and a supply voltage of 12.6/14.8 V, for currents:;14.1 - 1000 mA – <br>less than 0,1%. <br>1 - 10 mA – less than 0,2% (output current value is defined as the average value of positive and negative polarity currents); 14.1 - 1000 mA – <br>less than 0,1%. <br>1 - 10 mA – less than 0,25% (output current value is defined as the average value of positive and negative polarity currents);less than 0,25% (output current value is defined as the average value of positive and negative polarity currents)
Drift of output currents in the operating temperature range relative to the values at +20°C;less than ±0.5% (output current value is defined as the average of positive and negative polarity currents);less than ±0.5% (output current value is defined as the average of positive and negative polarity currents);less than ±0.5% (output current value is defined as the average of positive and negative polarity currents).
Relative error of frequency formation, including drift in the operating temperature range and aging during the first year of operation, less than; 5⋅10<sup>-6</sup>;5⋅10<sup>-6</sup>;5⋅10<sup>-6</sup>
Duration of current edge of RPI-1 on active load of 1 kOhm, not more;2 µs;2 µs;2 µs
Operating temperature range; from - 20°C to + 50°C, without condensation;from - 20°C to + 50°C, without condensation;from - 20°C to + 50°C, without condensation
Mode of operation; continuous, in field conditions, but without direct exposure to atmospheric precipitation;continuous, in field conditions, but without direct exposure to atmospheric precipitation;continuous, in field conditions, but without direct exposure to atmospheric precipitation
Supply voltage;12,6 V (Pb battery)<br>14,8 V (Li-Po battery)<br>minimum 10.5 V, maximum 17 V; 12,6 V <br>minimum 10,5 V, maximum 14,8 V;12,6 V (Pb battery)<br>14,8 V (Li-Po battery)<br>minimum 10.5 В, maximum 17 В
Current consumption;not more than 2,5 А;not more than 12 А;not more than 12 А
Weight;<b>~ 0.4 kg</b>;~ 2.0 kg;~ 1.1 kg
Dimensions;140х110х38 mm;200х173х113 mm;170х140х55 mm
Control;—<br><br> In external control mode - using Astra-20 program via a smartphone with Android 9 and later operating system.;In autonomous mode - keypad and 4-strigs display.;In autonomous mode - keypad and 1-string display.<br>In external control mode - using Astra-100AT program via a smartphone with Android 9 and later operating system.
Connection interface;Bluetooth in SPP mode (Serial Port Profile); —; Wi-Fi connection
Sound indication;- generation (optionally),<br>- AB line break,<br>- load more than 99%,<br>- load less than 2%,<br>- low supply voltage,<br>- overheating;- generation (optionally),<br>- AB line break,<br>- load more than 99%,<br>- load less than 2%,<br>- low supply voltage,<br>- overheating;- generation (optionally),<br>- AB line break,<br>- load more than 99%,<br>- load less than 2%,<br>- low supply voltage,<br>- overheating
Sockets;- AB line<br>- shut 10 Ohm ±1%<br>- supply;- AB line<br>- shut 1 Ohm ±1%<br>- supply<br>- synchronization;- AB line<br>- shut 1 Ohm ±0.25%<br>- supply
Hermetically sealed metal case;Standard IP-65;Standard IP-65;Standard IP-65